Hot-water heating panels

- This station is used to separate the heating loop and Thermo W (water) heating circuit

- Trouble-free venting.

- Indication of water level in the system.

- Secured against heating failures.

- Decreased corrosion (lesser amount of circulating water).

- The internals are copper, external enclosure made of high-quality steel.

 

The exchanger expansion tank must be located at the highest point of the system. Boiler-supplied water inlet must be connected to the back one of the two water line connections. The outlet is connected to the front connections. The pump must be directed downwards. Maximum pressure – primary loop 1 Mpa, secondary loop 0.6 Mpa. Warm-water circulation pump – input power 99W, 230V, 50 Hz, pump flow rate 3.4 cubic meters per hour.